Alternador de cobre sin escobillas de 7kVA hasta 2500KVA.
|
3Fases/50Hz/400 V/PF=0.8 |
3Fases/60Hz/440V/PF=0.8 |
El modelo |
KW (PR) |
KVA(PR) |
KW(ESP) |
KVA(ESP) |
KW(PR) |
KVA(PR) |
KW(ESP) |
KVA(ESP) |
S164G65B1 |
6.5 |
8.1. |
7 |
8.8 |
7.8 |
9.8 |
8.4 |
10.5 |
S164G88B2 |
8.8 |
11 |
9.5 |
11.9 |
10.6 |
13.2 |
11.4 |
14.3 |
S164G108B3 |
10.8 |
13.5 |
11.8 |
14.8 |
13 |
16.2 |
14.2 |
17.7 |
S164G128C4 |
12.8 |
16 |
14 |
17.5 |
15.4 |
19.2 |
16.8 |
21 |
S164G14C5 |
14 |
17.5 |
15.4 |
19.3 |
16.8 |
21 |
18.5 |
23.1 |
S184G16C6 |
16 |
20 |
17.6 |
22 |
19.2 |
24 |
211. |
26.4 |
S184G18D7 |
18 |
22.5 |
20 |
25 |
21.6 |
27 |
24 |
30 |
S184G20D8 |
20 |
25 |
22 |
27.5 |
24 |
30 |
26.4 |
33 |
S184G22D9 |
22 |
27.5 |
24.8 |
31 |
26.4 |
33 |
29.8 |
37.2 |
S184G25D10 |
25 |
31.25 |
28 |
35 |
30 |
37.5 |
33.6 |
42 |
S184G28E11 |
28 |
35 |
31 |
38,75 |
33.6 |
42 |
37.2 |
46.5 |
S184G30E12 |
30 |
37.5 |
33 |
41.25 |
36 |
45 |
39.6 |
49.5 |
S184G32E13 |
32 |
40 |
35 |
43.8 |
38.4 |
48 |
42 |
52.5 |
S224G32B1 |
32 |
40 |
35.2 |
44 |
38.4 |
48 |
42.2 |
52.8 |
S224G34B2 |
34 |
42.5 |
37.4 |
46.8 |
40.8 |
51 |
44.9 |
56.1 |
S224G40B3 |
40 |
50 |
44 |
55 |
48 |
60 |
52.8 |
66 |
S224G45B4 |
45 |
El 56,3 |
49.5 |
61.9 |
54 |
67.6 |
59.4 |
74.4 |
S224G50C5 |
50 |
62.5 |
55 |
68.8 |
60 |
75 |
66 |
82.5 |
S224G54C6 |
54 |
67.5 |
59.4 |
74.3 |
64.8 |
81 |
71.3 |
El 89,1% |
S224G58C7 |
58 |
72.5 |
65 |
81.3 |
69.6 |
87 |
76.5 |
95.7 |
S224G64D8 |
64 |
80 |
70 |
87.5 |
El 76,8 |
96 |
84.5 |
105.6 |
S224G68D9 |
68 |
85 |
75 |
93.8 |
81.6 |
102 |
89.8 |
112.2 |
S224G75D10 |
75 |
93.8 |
82.5 |
103.1 |
90 |
112.5 |
99 |
123,8 |
S274G80B1 |
80 |
100 |
88 |
110 |
96 |
120 |
106 |
132 |
S274G90B2 |
90 |
112.5 |
99 |
123.75 |
108 |
135 |
119 |
149 |
S274G100B3 |
100 |
125 |
110 |
137.5 |
120 |
150 |
132 |
165 |
S274G112C4 |
112 |
140 |
122 |
152,5 |
134 |
168 |
147 |
185 |
S274G120C5 |
120 |
150 |
132 |
165 |
144 |
180 |
158 |
198 |
S274G128C6 |
128 |
160 |
140 |
175 |
154 |
192 |
169 |
211 |
S274G140C7 |
140 |
175 |
154 |
192.5 |
168 |
210 |
185 |
231 |
S274G150D8 |
150 |
187.5 |
165 |
206.25 |
180 |
225 |
198 |
248 |
S274G160D9 |
160 |
200 |
176 |
220 |
192 |
240 |
211 |
264 |
S274G180E10. |
180 |
225 |
196 |
245 |
216 |
270 |
238 |
297 |
S274G200E11 |
200 |
250 |
220 |
275 |
240 |
300 |
264 |
330 |
S314G200D1 |
200 |
250 |
220 |
275 |
240 |
300 |
264 |
330 |
S314G220D2 |
220 |
275 |
242 |
303 |
264 |
330 |
290 |
363 |
S314G240D3 |
240 |
300 |
264 |
330 |
288 |
360 |
305 |
381 |
S314G250D4 |
250 |
313 |
275 |
344 |
300 |
375 |
330 |
413 |
S314G260D5 |
260 |
325 |
286 |
358 |
312 |
390 |
343 |
429 |
S314G280D6 |
280 |
350 |
308 |
385 |
336 |
420 |
370 |
462 |
S314G300E7 |
300 |
375 |
330 |
413 |
360 |
450 |
396 |
495 |
S314G320E8 |
320 |
400 |
352 |
440 |
384 |
480 |
422 |
528 |
S314G360E9 |
360 |
450 |
396 |
495 |
432 |
540 |
474 |
593 |
S354G360D1 |
360 |
450 |
396 |
495 |
432 |
540 |
475 |
594 |
S354G400D2 |
400 |
500 |
440 |
550 |
480 |
600 |
528 |
660. |
S354G430D3 |
430 |
538 |
473 |
592 |
516 |
646 |
568 |
711. |
S354G450D4 |
450 |
563 |
495 |
619 |
540 |
676 |
594 |
744 |
S354G480D5 |
480 |
600 |
528 |
660. |
576 |
720. |
634 |
792 |
S354G500D6 |
500 |
625 |
550 |
688 |
600 |
750 |
660. |
825 |
S354G520E7 |
520 |
650 |
572 |
715 |
624 |
780 |
686 |
858 |
S354G540E8 |
540 |
675 |
594 |
743 |
648 |
810 |
713 |
891 |
S354G560E9 |
560 |
700 |
616 |
770 |
672 |
840 |
739 |
924 |
S354G600E10. |
600 |
750 |
660. |
825 |
720. |
900 |
792 |
990 |
Alternador sin escobillas para grupo electrógeno diesel 7kVA hasta 2500kVA.
|
Alternadores sin escobillas de la serie SVC - Stamford technology |
El tamaño de fotograma (mm) |
El bastidor de 044-734 |
KVA. |
A partir de 7kVA hasta 2500kVA. |
La tensión nominal |
220V, 380V, 400V, 415V, 440V |
Frecuencia |
50Hz/60Hz |
La clase de protección Y la clase de aislamiento |
IP21, IP23, Clase H |
Los polacos |
2 - 4 |
La temperatura del aire de refrigeración |
258-313K(-15ºC-40ºC) |
El Índice de Rendimiento principal |
♦tres fase cuatro hilos ♦Ajuste de la velocidad de la tensión estable ≤ ±1% ♦estado transitorio tensión ≤ -15% ~ +20% ♦la aberración de onda de tensión de la tasa de THD ≤2% ♦armonía Teléfono ola factor teléfono THF ≤2% ♦Teléfono factor eficaz por teléfono TIF ≤2% |
Características |
♦AVR y el sistema fiable de emocionante opcional sistema magnético permanente siempre proporcionan excitación invariable en todas las ocasiones. ♦fácil estar conectado con red eléctrica de forma paralela a otros generadores. ♦rotor equilibrado, sellado individuales y dobles de rodamientos de bolas. ♦instalación cómoda y fácil mantenimiento, de fácil acceso a la terminal. Girar el rectificador| y pernos de acoplamiento. ♦Amplia gama de adaptador de brida y el disco de acoplamiento para un solo rodamiento. ♦en conformidad con todos los continente estándar. |
Característica opcional |
♦Adaptadores y disco de la unidad intercambiable ♦monofásico ♦ajuste de tensión de mando a distancia ♦Clase de protección IP23 ♦los calentadores ♦termistores |
Aplicaciones de los campos |
Para ser instaladas en el generador diesel, o suspender el suministro de alimentación continua. |