• Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
  • Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
  • Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
  • Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
  • Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
  • Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Favoritos

Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits

Proceso de dar un título: Ticw
Color: Black / Red / Grey
Clasificación IP: IP68
Uso: Cable Joint
Material: EDUCACIÓN FÍSICA
Escribe: 1~5-Cores

Contactar al Proveedor

Fabricante/Fábrica & Empresa Comercial

Tour Virtual 360 °

Miembro Diamante Desde 2023

Proveedores con licencias comerciales verificadas

Jiangsu, China
Cooperó con Fortune 500
Este proveedor ha cooperado con empresas Fortune 500.
Años de Experiencia Exportadora
La experiencia exportadora del proveedor es de más de 10 años.
Patentes concedidas
El proveedor había otorgado 3 patentes, puede consultar el Audit Report para obtener más información
Certificación de Gestión
El proveedor cuenta con certificación del sistema de gestión de calidad, que incluye:
ISO9001:2015 certificate
ISO45001:2018 certificate
para ver todas las etiquetas de fortaleza verificadas (27)
  • Visión General
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Recommended Product
  • Company Profile
  • Packaging & Shipping
  • FAQ
Visión General

Información Básica.

No. de Modelo.
VSZ / VSJ / VRSN / VRSJ / VRSW / VRLN / VRLJ
capa de aislamiento
2mm
estándar
GB811-P5
clase de tensión
LV & Mv (35kv and Below)
temperatura
-50 ~105
Paquete de Transporte
Carton
Especificación
Varous
Marca Comercial
9V
Origen
Jiangsu, China
Código del HS
8547909000

Descripción de Producto

 
Product Description

Heat-shrinkable cable terminals
It commonly known as heat-shrinkable cable heads, are widely used on the terminals of cross-linked cables or oil-immersed cables with voltage levels of 35KV and below. Compared with the traditional cable accessories, the intermediate connection of the cable has the characteristics of small size, light weight, safety and reliability, and convenient installation.

Detailed Photos
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
 
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Product Parameters

0.6/1KV-Heat Shrinkable Cable Accessories

Name Item No. Suit cables' sectional area (sqmm) Name Item No. Suit cables' sectional area (sqmm)
0.6/1kV Single Core Heat Shrinkable Termination Kits VSZ-1/1.0 10~16 0.6/1kV Single Core Heat Shrinkable Joint VSJ-1/1.0 10~16
VSZ-1/1.1 25~50 VSJ-1/1.1 25~50
VSZ-1/1.2 70~120 VSJ-1/1.2 70~120
VSZ-1/1.3 150~240 VSJ-1/1.3 150~240
VSZ-1/1.4 300~400 VSJ-1/1.4 300~400
0.6/1kV 2-cores Heat Shrinkable Termination Kits VSZ-1/2.0 10~16 0.6/1kV 2-cores Heat Shrinkable Joint VSJ-1/2.0 10~16
VSZ-1/2.1 25~50 VSJ-1/2.1 25~50
VSZ-1/2.2 70~120 VSJ-1/2.2 70~120
VSZ-1/2.3 150~240 VSJ-1/2.3 150~240
VSZ-1/2.4 300~400 VSJ-1/2.4 300~400
0.6/1kV 3-cores Heat Shrinkable Termination Kits VSZ-1/3.0 10~16 0.6/1kV 3-cores Heat Shrinkable Joint VSJ-1/3.0 10~16
VSZ-1/3.1 25~50 VSJ-1/3.1 25~50
VSZ-1/3.2 70~120 VSJ-1/3.2 70~120
VSZ-1/3.3 150~240 VSJ-1/3.3 150~240
VSZ-1/3.4 300~400 VSJ-1/3.4 300~400
0.6/1kV 4-cores Heat Shrinkable Termination Kits VSZ-1/4.0 10~16 0.6/1kV 4-cores Heat Shrinkable Joint VSJ-1/4.0 10~16
VSZ-1/4.1 25~50 VSJ-1/4.1 25~50
VSZ-1/4.2 70~120 VSJ-1/4.2 70~120
VSZ-1/4.3 150~240 VSJ-1/4.3 150~240
VSZ-1/4.4 300~400 VSJ-1/4.4 300~400
0.6/1kV 5-cores Heat Shrinkable Termination Kits VSZ-1/5.0 10~16 0.6/1kV 5-cores Heat Shrinkable Joint VSJ-1/5.0 10~16
VSZ-1/5.1 25~50 VSJ-1/5.1 25~50
VSZ-1/5.2 70~120 VSJ-1/5.2 70~120
VSZ-1/5.3 150~240 VSJ-1/5.3 150~240
VSZ-1/5.4 300~400 VSJ-1/5.4 300~400
Test Project Test Method Test Result/Conclusion
1min Power Frequency Voltage (wet state) 4kV, No breakdown no flashover No flashover and breakdown of the combined sample under 4kV, 1min wet state
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
4H Power Frequency Voltage Test 2.4kV, No breakdown no flashover No flashover and breakdown of combined specimens
8.7/15KV-Heat Shrinkable Cable Accessories
Name Item No. Suit cables' sectional area (sqmm) Name Item No. Suit cables' sectional area (sqmm)
8.7/15kV Single Core Heat Shrinkable Indoor Termination Kits VRSN-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Indoor Termination Kits VRSN-10/3.1 25~50
VRSN-10/1.2 70~120 VRSN-10/3.2 70~120
VRSN-10/1.3 150~240 VRSN-10/3.3 150~240
VRSN-10/1.4 300~400 VRSN-10/3.4 300~400
VRSN-10/1.5 500~630 VRSN-10/3.5 500~630
8.7/15kV Single Core Heat Shrinkable Outdoor Termination Kits VRSW-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Outdoor Termination Kits VRSW-10/3.1 25~50
VRSW-10/1.2 70~120 VRSW-10/3.2 70~120
VRSW-10/1.3 150~240 VRSW-10/3.3 150~240
VRSW-10/1.4 300~400 VRSW-10/3.4 300~400
VRSW-10/1.5 500~630 VRSW-10/3.5 500~630
8.7/15kV Single Core Heat Shrinkable Joint VRSJ-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Joint VRSJ-10/3.1 25~50
VRSJ-10/1.2 70~120 VRSJ-10/3.2 70~120
VRSJ-10/1.3 150~240 VRSJ-10/3.3 150~240
VRSJ-10/1.4 300~400 VRSJ-10/3.4 300~400
VRSJ-10/1.5 500~630 VRSJ-10/3.5 500~630
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 45kV, No breakdown no flashover No flashover and breakdown of the combined sample under 45kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC 13kV≤20PC A, B, C three-phase discharge capacity is 2PC under 13kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 105kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 105kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 52kV, No breakdown no flashover 52kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 35kV, No breakdown no flashover 35kV, 4h, No flashover and breakdown of combined specimens

12/20KV 18/20KV-Heat Shrinkable Cable Accessories
 
Name Spec. (Single Core) Spec. (3-cores) Suit cables' sectional area (sqmm)
12/20kV 18/20kV
12/20kV Single Core / 3-cores Heat Shrinkable Indoor Termination Kits VRSN-20/1.1 VRSN-20/3.1 35~70 ------
VRSN-20/1.2 VRSN-20/3.2 95~185 35~70
VRSN-20/1.3 VRSN-20/3.3 240~400 95~185
VRSN-20/1.4 VRSN-20/3.4 500~630 240~400
12/20kV Single Core / 3-cores Heat Shrinkable Outdoor Termination Kits VRSW-20/1.1 VRSW-20/3.1 35~70 ------
VRSW-20/1.2 VRSW-20/3.2 95~185 35~70
VRSW-20/1.3 VRSW-20/3.3 240~400 95~185
VRSW-20/1.4 VRSW-20/3.4 500~630 240~400
12/20kV Single Core / 3-cores  Heat Shrinkable Joint VRSJ-20/1.1 VRSJ-20/3.1 35~70 ------
VRSJ-20/1.2 VRSJ-20/3.2 95~185 35~70
VRSJ-20/1.3 VRSJ-20/3.3 240~400 95~185
VRSJ-20/1.4 VRSJ-20/3.4 500~630 240~400
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 54kV, No breakdown no flashover No flashover and breakdown of the combined sample under 54kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC 20kV≤20PC A, B, C three-phase discharge capacity is 1pc under 20kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 125kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 125kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 156kV, No breakdown no flashover 156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 104kV, No breakdown no flashover 104kV, 4h, No flashover and breakdown of combined specimens
 
26/35KV-Heat Shrinkable Cable Accessories
Name Item No. Suit cables' sectional area (sqmm) Name Item No. Suit cables' sectional area (sqmm)
26/35kV Single Core Heat Shrinkable Indoor Termination Kits VRLN-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Indoor Termination Kits VRLN-35/3.1 50~95
VRLN-35/1.2 120~185 VRLN-35/3.2 120~185
VRLN-35/1.3 240~400 VRLN-35/3.3 240~400
VRLN-35/1.4 500~630 VRLN-35/3.4 500~630
26/35kV Single Core Heat Shrinkable Outdoor Termination Kits VRLW-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Outdoor Termination Kits VRLW-35/3.1 50~95
VRLW-35/1.2 120~185 VRLW-35/3.2 120~185
VRLW-35/1.3 240~400 VRLW-35/3.3 240~400
VRLW-35/1.4 500~630 VRLW-35/3.4 500~630
26/35kV Single Core Heat Shrinkable Joint VRLJ-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Joint VRLJ-35/3.1 50~95
VRLJ-35/1.2 120~185 VRLJ-35/3.2 120~185
VRLJ-35/1.3 240~400 VRLJ-35/3.3 240~400
VRLJ-35/1.4 500~630 VRLJ-35/3.4 500~630
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 105kV, No breakdown no flashover No flashover and breakdown of the combined sample under 105kV, 1min wet state
Partial discharge test 13kV devolution power not more than 10PC 39kV≤10PC A, B, C three-phase discharge capacity is 4pc under 39kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 250kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 250kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 156kV, No breakdown no flashover 156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 104kV, No breakdown no flashover 104kV, 4h, No flashover and breakdown of combined specimens
 
Recommended Product

View more products,you can click photos...

Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits

     66~500kV High Voltage Cable Accessories              1~35kV Cold Shrink Cable Accessories                                        Grounding Box

Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits

      Customized Silicone Rubber Protector                                Heat Shrinkable Tubing                                                  Explosion Proof Box

Company Profile
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint KitsFactory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint KitsFactory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint KitsFactory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
Packaging & Shipping

Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
FAQ
Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits
 

Enviar directamente tu consulta a este proveedor

*De:
*A:
*Mensaje:

Pone entre 20 y 4000 caracteres.

Esto no es lo que buscas? Publique Solicitud de Compra Ahora

Buscar Productos Similares Por Categoría

Página Web del Proveedor Productos Accesorios de cable termorretráctil Factory Supply 8.7/15kv 3-Core Cable Heat Shrinkable Straight Joint Kits