Type: | Air-Cooled |
---|---|
Cooling Method: | Air-cooled |
Unit Structure: | Integral |
Selected Voltage: | 220V, 380V, 160V, 440V etc. |
Compressor Number: | It Depend on The Cooling Capacity |
Noise Level: | Ultra Low |
Proveedores con licencias comerciales verificadas
El tipo de elemento | HWAC15 | HWAC18 | HWAC20 | HWAC25 | HWAC30 | HWAC36 | HWAC40 | HWAC50 | HWAC60 | HWAC75 | HWAC85. | HWAC100 | ||
HWAC15H | HWAC18H | HWAC20H | HWAC25H | HWAC30H | HWAC36H | HWAC40H | HWAC50H | HWAC60H | HWAC75H | HWAC85H | HWAC100H | |||
La capacidad de refrigeracióN | KW | 39 | 47 | 52 | 65 | 78 | 102 | 112 | 135 | 160 | 198 | 220 | 250 | |
Capacidad de calefaccióN | KW | 41 | 50 | 55 | 68 | 82 | 105 | 117 | 140 | 166 | 206 | 230 | 263 | |
Fuente de AlimentacióN | 380V/3PH-50Hz | |||||||||||||
Entrada de la potencia de refrigeracióN | KW | 14 | 16.5 | 18 | 21.5 | 26.9 | 32.8 | 37 | 44 | 55 | 72 | 84 | 95 | |
Entrada de energíA de calefaccióN | KW | 14.8 | 17.4 | 19 | 22.6 | 28 | 34 | 38.4 | 45.6 | 56.8 | 74 | 86 | 98 | |
Los Dispositivos de proteccióN | La alta& Interruptor de presióN baja, Anti- Protector de congelados, Protector de carga, Orden de la fase De calor, protector Protector, Interruptor de flujo de agua Protector, Protector del sensor de temperatura, | |||||||||||||
Funcionamiento Y Control | Control de microcomputadora ,automáTicamente AVISO DE AVERIA QUE Equilibrar El Tiempo de operacióN, Control remoto (opcional),Timer On/off , CalefaccióN eléCtrica auxiliar (opcional). | |||||||||||||
El compresor | Tipo | Compresor Scroll herméTico | ||||||||||||
La alimentacióN | 3,75×3 | 4.5×3 | 3,75*4 | 9×2 | 9×2+3.75 | 9×3 | 9×3+3.75 | 9×4 | 9×5 | 9×6 | 9×7 | 9×8 | ||
Lado del aire Del Intercambiador de calor | Tipo de intercambiador | Las aletas de aluminio con tubos de cobre | ||||||||||||
Tipo de ventilador | Ruido ultra bajo Axial | |||||||||||||
La direccióN de soplado de aire | Descarga top | |||||||||||||
El Flujo de aire | M3/h | 17000 | 18000 | 20000 | 27000 | 32000 | 36000 | 41000 | 54000 | 63000 | 73000 | 80000 | 105000 | |
La alimentacióN | KW | 0,55×2 | 0,55×2 | 0,75×2 | 1.1×2 | 1.5×2 | 1.1×3 | 0,55×4 | 1.1×4 | 1.5×4 | 1.1×6 | 1.1×6 | 1.1*8 | |
Intercambiador de calor del lado de agua | Tipo | Shell Y el Tubo | ||||||||||||
El Flujo de agua | M3/h | 7.5 | 9 | 10 | 12 | 15 | 20 | 22 | 24 | 30 | 36 | 40 | 46 | |
Resistencia al agua | KPa | 46 | 46 | 48 | 48 | 50 | 50 | 50 | 52 | 52 | 52 | 53 | 53 | |
El tubo de conexióN | Pulgadas/mm | 1 1/2"/DN40 | 1 1/2"/DN40 | 2"/DN50 | 2"/DN50 | 2 1/2"/DN65 | 2 1/2"/DN65 | 2 1/2"/DN65 | 2 1/2"/DN65 | 3"/DN80 | 3"/DN80 | 4"/DN100 | 4"/DN100 | |
El refrigerante | R22/R407C | |||||||||||||
El volumen Vontrol | VáLvula de expansióN termostáTica | |||||||||||||
El ruido de funcionamiento | DB(A) | 63 | 63 | 64 | 64 | 67 | 67 | 68 | 68 | 71 | 71 | 71 | 73 | |
Dimensiones | L*W*H | Mm | 2000*1000*1800 | 2000*1000*1950 | 2200*1000*1900 | 2200*1000*1950 | 2500*1100*2100 | 3100*1100*2100 | 2000*2000*1950 | 2300*2100*2000 | 2400*2200*2100 | 3100*2200*2100 | 3200*2400*2200 | 4300*2200*2200 |
El peso | Kg. | 580 | 650 | 880 | 930 | 980. | 1020. | 1250 | 1310 | 1470 | 1580 | 1660 | 1870 | |
Nota: | ||||||||||||||
1. Fuente de alimentacióN opcional : 440V/3PH/60Hz y 220V/3PH/60Hz. | ||||||||||||||
2."H" Significa el Tipo de bomba de calor, No Significa SóLo enfriamiento Tipo. | ||||||||||||||
3. RefrigeracióN nominal CondicióN: La temperatura del Aire DB35ºC/WB24ºC, Temperatura del agua de entrada/salida 12/7º. | ||||||||||||||
4. Calentamiento de la nominal CondicióN: La temperatura del Aire DB7ºC/WB6ºC, Temperatura del agua de entrada/salida de 40/45ºC. | ||||||||||||||
5. Debido A Los Avances tecnolóGicos, Por encima de Las especificaciones EstáN Sujetas A Cambios Sin Previo aviso. |
Proveedores con licencias comerciales verificadas