• Woltman Cold Water Meters with RS485 Used for Water Utilities
  • Woltman Cold Water Meters with RS485 Used for Water Utilities
  • Woltman Cold Water Meters with RS485 Used for Water Utilities
  • Woltman Cold Water Meters with RS485 Used for Water Utilities
  • Woltman Cold Water Meters with RS485 Used for Water Utilities
  • Woltman Cold Water Meters with RS485 Used for Water Utilities
Favoritos

Woltman Cold Water Meters with RS485 Used for Water Utilities

After-sales Service: 1 Year
Warranty: 1 Year
Install: Horizontal
Medium Temperature: Cold Water
Level Measurement: B
Counter Instructions: Digital and Analogue

Contactar al Proveedor

Fabricante/Fábrica & Empresa Comercial

Tour Virtual 360 °

Miembro Diamante Desde 2023

Proveedores con licencias comerciales verificadas

Hebei, China
Importadores y Exportadores
El proveedor tiene derechos de importación y exportación.
Seguro de calidad
El proveedor proporciona garantía de calidad.
Trazabilidad de Materias Primas
El proveedor cuenta con identificación de trazabilidad de las materias primas.
Certificación de Gestión
El proveedor cuenta con certificación del sistema de gestión de calidad, que incluye:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
ISO10012 Certificate
Service Certificate
para ver todas las etiquetas de fortaleza verificadas (27)
  • Visión General
  • Company Profile
Visión General

Información Básica.

No. de Modelo.
ws-50
Nominal Diameter
50-100mm
Application
Civil, Industrial
Principle
Speed of Water Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Stucture
Wireless Communicating
tipo
Horizontal Spiral Vane
estilo
Muti-Jet
temperatura
T50
muestreo
Magnetoresistive or Reed Switch
tamaño
dn50-dn300
máximo
63mpa
Paquete de Transporte
Carton with Foam
Especificación
dn50-dn300
Marca Comercial
Daocheng
Origen
Hebei
Código del HS
9028201000
Capacidad de Producción
1500000 PCS/Year

Descripción de Producto

Woltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water Utilities
The Product Detail
Woltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water Utilities

item
value
Warranty
3 years
Customized support
OEM, ODM, OBM
Place of Origin
China
 
Hebei
Brand Name
DaoCheng
Model Number
WS-50
Type
Multi-jet meters, Compound meters, Turbine meters, Electromagnetic meters
Product name
woltman water flow meter with remote
Material
Cast Iron
Application
Commercial
Water temperature
Cold Water 0.1 ~50
Battery Life
6-8 Years
Max working pressure
1.0 MPa
Communication mode
RS-485/M-BUS/Pulse/Lora/GPRS/GSM/NB-IoT
Q3/Q1
200
Nominal Diameter
DN50-DN200
Protection class
IP 68
Size 
50/80/100/150/200/300 mm


Application

This model of water meter is used to record the total amount of cold water flowing through the pipeline. It cannot be used to measure sewage and corrosive liquids.

Feature

1.       Using non-contact sensors, does not affect the original performance of mechanical water meters.

2.       Using infrared radiation to enhance the anti-interference ability; non-mechanical contact mode, will not cause garbled reading due to mechanical looseness.

3.       Special coding method, there is no dead zone of reading, the mechanical rotation can keep the mechanical reading consistent with the electronic reading when the word wheel is rotated to any position.

4.       Low power design, only power is required for reading.

5.       Can be combined with the meter reading system to establish a remote automatic meter reading management system to truly realize meter reading automation.

6.       The electronic device complies with the standard of Electronic Remote Water Meter (CJ/T224-2012)

7.       The agreement is in line with the "Technical Conditions for Data Transmission of Household Meters" CJ/T188-2004 or MODBUS or both parties.

Conditions of Use

1.       Water temperature: 0~ 30°C Pressure: no more than 1MPa Working environment: Class B

2.       Upstream flow field sensitivity level: U10 Downstream flow field sensitivity level: D5

3.       Transmission mode is divided into RS-485, MBUS bus transmission mode.

4.       Communication transmission rate: 2400bps or customized according to customer requirements; Maximum distance for communication transmission: 1000m

The main technical parameters

 

Indication error limit

1.       The maximum allowable error from the minimum flow (Q1) to the low zone that does not include the boundary flow (Q2) is ±5%

2.       The maximum allowable error from the high boundary including the boundary flow (Q2) to the overload flow (Q4) is ±2%

Dimensions and weight

Removable screw-wing water meter

 

Installation and use

1.       Determine the diameter of the water meter. Firstly, understand the flow rate in the pipeline. It is better to use the flow rate close to the common flow. It is not possible to determine the diameter of the water meter simply by the diameter of the pipeline.

2.       The upstream and downstream of the water meter should be installed with the necessary straight pipe section or the equivalent of the water flow rectifier. The length of the upstream straight pipe section is not less than 10D, and the downstream straight pipe section is not less than 5D (D is the nominal diameter of the water meter). The rotation of the water flow caused by the elbow or the centrifugal pump, it is necessary to install the rectifier in front of the straight pipe section.

3.       Newly installed pipelines should be cleaned of stones, muddy water and other debris in the pipeline and installed with water meters to prevent damage or malfunction of the water meters.

4.       Install a filter with the same nominal diameter of the water meter in the upstream of the water meter. The filter should be taken out and cleaned frequently. The debris accumulated in the filter should be cleaned to ensure accurate metering.

5.       The water meter should be installed coaxially with the upper and lower straight pipe sections, and the gasket should not protrude into the pipe to avoid the measurement uncertainty.

6.       Installation location should avoid exposure, freezing, pollution and flooding, in order to disassemble and read the meter.

7.       The water meter installation should be bypassed to ensure that the water meter is not stopped when the water meter is installed. Water meter installation should pay attention to the water flow and the direction of the arrow on the water case to prevent the reverse installation, the valve should be installed upstream and downstream of the water meter, and all open when used.

8.       Prevent the steam from entering the pipeline directly when installing the hot water meter.
 

Company Profile


Woltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water UtilitiesWoltman Cold Water Meters with RS485 Used for Water Utilities
 

 

Enviar directamente tu consulta a este proveedor

*De:
*A:
*Mensaje:

Pone entre 20 y 4000 caracteres.

Esto no es lo que buscas? Publique Solicitud de Compra Ahora

Também Poderá Querer

Contactar al Proveedor

Miembro Diamante Desde 2023

Proveedores con licencias comerciales verificadas

Fabricante/Fábrica & Empresa Comercial
Número de Empleados
120
Año de Establecimiento
2014-07-01