• Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
  • Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
  • Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Favoritos

Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs

Certificación: RoHS, CCC, ISO: 9001, CE
Condición: Nueva
Personalizado: No personalizado
número de canales: 2inputs/2outputs
señal de entrada: rango de medición del termopar correspondiente
señal de salida: 4ma~20ma

Contactar al Proveedor

Fabricante/Fábrica & Empresa Comercial

Tour Virtual 360 °

Miembro Diamante Desde 2024

Proveedores con licencias comerciales verificadas

Jiangsu, China
Marca propia
El proveedor tiene 2 marcas propias, consulte el Audit Report para obtener más información.
para ver todas las etiquetas de fortaleza verificadas (26)
  • Visión General
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Overall dimension
  • Company Profile
Visión General

Información Básica.

No. de Modelo.
DRG-1520
modo de fuente de alimentación
20~35v dc
precisión
0,2% f.s. (valor típico: 0,05% f.s.)
instalación
35mm carril din
Paquete de Transporte
Caja
Especificación
PC+ABSflame retardant
Marca Comercial
PARAGON
Origen
China

Descripción de Producto

Product Description
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Detailed Photos
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Product Parameters
General
Number of channels 2inputs/2outputs
Output accuracy (20 ° C) 0.2% F.S. (typical value: 0.05% F.S.)
Temperature drift 0.01%F.S./ºC
Cold end compensation accuracy ±1ºC(0ºC~55ºC)
Response time 2ms to reach 90% of the final value
Insulation strength 1500VAC/min between intrinsically safe/non intrinsically safe terminals, 1000VAC/min between non intrinsically safe terminals
Insulation resistance Non intrinsic safety end - intrinsic safety end≥100MΩ, power supply - non intrinsic safety end≥100MΩ
Electromagnetic compatibility Compliant with IEC 61326-1(GB/T 18268),IEC 61326-3-1
EX marking [Ex ia Ga]IIC
Weight About 150g
Connected field equipment J,K,T,E,S,B,N,Rthermocouple
Applicable locations Zone 0, Zone 1, Zone 2, IIA, IIB, IIC hazardous areas
Input data
Input signal range Corresponding thermocouple measurement range
Input signal type Thermocouple millivolt signal (K, S, B, E, J, T, N, R, We5-26)
Output data
Output signal 4mA~20mA
Output load capacity 0~500Ω
Power supply
Supply voltage(Ue) 20~35V DC
Power protection Reverse protection of power supply
Power consumption 1W (24V power supply, 20mA output)
Power supply mode Independent power supply
Power connecting mode Terminal power supply;Base power supply
Overall dimension
Centralized power supply
Depth 120.8mm
Height 113mm
Width 13.3mm
Independent power supply
Depth 110mm
Height 108mm
Width 13.3mm
Housing
Material PC+ABSflame retardant
Degree of protection IP20
Flammability rating UL94/V0
Colour White+Grey
EMC data
Electrical fast transient/burst immunity Compliant with:IEC 61326-1;A-leve
Surge immunity Compliant with:IEC 61326-1;B-leve
Radiated,radio-frequency,electromagnetic field immunity Compliant with:IEC 61326-1;conform to basic requirements
Electrostatic discharge immunity Compliant with:IEC 61326-1;A-leve
Immunity to conducted disturbances, induced by radio-frequency fields Compliant with:IEC 61326-1;conform to basic requirements
Low frequency common mode conduction Compliant with:IEC 61326-1;conform to basic requirements
Operating conditions
Continuous operating temperature -20ºC~+60ºC
Storage temperature -40ºC~+80ºC
Relative humidity 35%~85%RH
Environmental requirements There should be no strong vibrations, impacts, high currents, sparks or other electromagnetic induction effects in the surrounding environment. The air should not contain media that corrode chromium, nickel, and silver coatings, and should not contain flammable or explosive substances
Connection data
Conductor cross section solid range 0.5~2.5mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M3
Stripping length 8mm
Connection method Screw connection
Tightening torque min. 0.5 Nm
Tightening torque max. 0.6 Nm
Installation
Installation method DIN35mm
Overall dimension
 1. Base centralized power supply typeDrg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs2. Terminal powered type

Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs

Company Profile

 


Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
 
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs
Drg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputsDrg-1520 Thermocouple/Millivolt Isolated Safety Barrier 2inputs/2outputs

Enviar directamente tu consulta a este proveedor

*De:
*A:
*Mensaje:

Pone entre 20 y 4000 caracteres.

Esto no es lo que buscas? Publique Solicitud de Compra Ahora