Descripción de Producto
Información de la Compañía
Información Básica.
No. de Modelo.
VV/VLV/VV22/VV32
Aplicación
Construcción, Subterráneo
Voltaje
Cable de Voltaje de Baja y Media
Material de aislamiento
PVC
Material de la Funda
None
Certificación
ISO, CE, SABS
No.of Cores
1, 2, 3, 4, 5, 3+1, 4+1, 3+2
Insulation Identification
Red, Yellow, Blue, Black, Green
Voltage Test
3.5kv for 5 Minutes, Insulation Not Breakdown
Curving Radius
Not Less Than 30d
Standards
IEC, BS, VDE, AS/NZS, Icea
Delivery Length
Accord with The Request
Paquete de Transporte
Wooden Drum or Wooden&Steel Drum
Especificación
IEC, ASTM, DIN, BS, GB, Any standard
Descripción de Producto
Copper Conductor Cable 0.6/1kV PVC Power Cable
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Unarmoured | Armoured |
Thickness of Sheath | Overall Dia. | jpcable99.en.made-in-china.com Weight | Thickness of Bedding | Thickness of Al Tape | Thickness of Sheath | Overall Dia. | jpcable99.en.made-in-china.com Weight |
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor |
mm2 | - | mm | mm | mm | kg/km | kg/km | mm | mm | mm | mm | kg/km | kg/km |
1.5 | 1 | 0.8 | 1.4 | 5.8 | - | 51 | - | - | - | - | - | - |
2.5 | 1 | 0.8 | 1.4 | 6.2 | - | 64 | - | - | - | - | - | - |
4 | 1 | 1 | 1.4 | 7.1 | - | 88 | - | - | - | - | - | - |
6 | 7 | 1 | 1.4 | 7.8 | 78 | 114 | - | - | - | - | - | - |
10 | 7 | 1 | 1.4 | 8.6 | 96 | 159 | 1 | 0.5 | 1.8 | 13.4 | 234 | 295 |
16 | 7 | 1 | 1.4 | 9.6 | 123 | 222 | 1 | 0.5 | 1.8 | 14.4 | 274 | 370 |
25 | 7 | 1.2 | 1.4 | 11.2 | 172 | 328 | 1 | 0.5 | 1.8 | 16 | 344 | 496 |
35 | 7 | 1.2 | 1.4 | 12.2 | 209 | 428 | 1 | 0.5 | 1.8 | 17 | 393 | 606 |
50 | 19 | 1.4 | 1.4 | 13.9 | 271 | 565 | 1 | 0.5 | 1.8 | 18.7 | 478 | 764 |
70 | 19 | 1.4 | 1.5 | 15.9 | 356 | 818 | 1 | 0.5 | 1.8 | 20.5 | 582 | 1020 |
95 | 19 | 1.6 | 1.5 | 18 | 471 | 1041 | 1 | 0.5 | 1.8 | 22.6 | 717 | 1291 |
120 | 37 | 1.6 | 1.6 | 19.6 | 563 | 1307 | 1 | 0.5 | 1.8 | 24 | 822 | 1545 |
150 | 37 | 1.8 | 1.6 | 21.3 | 684 | 1592 | 1 | 0.5 | 1.8 | 25.4 | 952 | 1857 |
185 | 37 | 2 | 1.7 | 23.9 | 840 | 1985 | 1 | 0.5 | 1.8 | 27.9 | 1136 | 2236 |
240 | 61 | 2.2 | 1.8 | 27 | 1071 | 2533 | 1 | 0.5 | 1.9 | 31 | 1404 | 2877 |
300 | 61 | 2.4 | 1.9 | 29.6 | 1317 | 3162 | 1.2 | 0.5 | 2.1 | 34.3 | 1722 | 3551 |
400 | 61 | 2.6 | 2 | 33.2 | 1666 | 4120 | 1.2 | 0.5 | 2.2 | 37.6 | 2114 | 4488 |
500 | 61 | 2.8 | 2.2 | 37.5 | 2089 | 5163 | 1.2 | 0.5 | 2.3 | 42.1 | 2592 | 5683 |
630 | 61 | 2.8 | 2.3 | 41.2 | 2581 | 6447 | 1.4 | 0.5 | 2.4 | 46.3 | 3184 | 7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight |
Al Conductor | Cu Conductor |
- | mm2 | - | mm | mm | mm | kg/km | kg/km |
Three Cores | 3x35 | 16 | 1.2 | 1.8 | 21.9 | 601 | 1280 |
3x50 | 18 | 1.4 | 1.8 | 26.5 | 829 | 1732 |
3x70 | 18 | 1.4 | 1.9 | 29.2 | 1067 | 2367 |
3x95 | 36 | 1.6 | 2 | 32.9 | 1409 | 2317 |
3x120 | 36 | 1.6 | 2.1 | 36.2 | 1705 | 3983 |
3x150 | 36 | 1.8 | 2.2 | 38.8 | 2045 | 4872 |
3x185 | 36 | 2 | 2.4 | 44.8 | 2596 | 6077 |
3x240 | 60 | 2.2 | 2.6 | 51.5 | 3353 | 7953 |
3x300 | 60 | 2.4 | 2.7 | 54.9 | 6069 | 9820 |
Four Cores with Reduced Neutral | 3x35+16 | 16-7 | 1.2-1 | 1.8 | 25.5 | 764 | 1107 |
3x50+25 | 18-16 | 1.4-1.2 | 1.9 | 28.7 | 982 | 1410 |
3x70+35 | 18-16 | 1.4-1.2 | 2.0 | 32 | 1278 | 1733 |
3x95+50 | 36-18 | 1.6-1.4 | 2.2 | 37.8 | 1711 | 2656 |
3x120+70 | 36-18 | 1.6-1.4 | 2.3 | 40.5 | 2065 | 3137 |
3x150+70 | 36-18 | 1.8-1.4 | 2.4 | 44.8 | 2480 | 3660 |
3x185+95 | 36-36 | 2-1.6 | 2.6 | 49.7 | 3086 | 4345 |
3x240+120 | 60-36 | 2.2-1.6 | 2.8 | 56 | 3894 | 5441 |
3x300+150 | 60-36 | 1.4-1.8 | 2.9 | 60.3 | 4834 | 6494 |
Four Cores | 4x25 | 16 | 1.2 | 1.8 | 22.5 | 644 | 1286 |
4x35 | 16 | 1.2 | 1.8 | 24.6 | 799 | 1696 |
4x50 | 18 | 1.4 | 1.8 | 28.6 | 1071 | 2275 |
4x70 | 18 | 1.4 | 2 | 31.6 | 1387 | 3120 |
4x95 | 36 | 1.6 | 2.1 | 35.9 | 1850 | 4262 |
4x120 | 36 | 1.6 | 2.2 | 38.8 | 2209 | 5247 |
4x150 | 36 | 1.8 | 2.3 | 43.1 | 2714 | 6483 |
4x185 | 36 | 2 | 2.5 | 48.7 | 3403 | 8045 |
4x240 | 60 | 2.2 | 2.7 | 53.6 | 4290 | 10422 |
4x300 | 60 | 2.4 | 2.9 | 58.8 | 5302 | 12969 |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight |
Al Conductor | Cu Conductor |
- | mm2 | - | mm | mm | mm | kg/km | kg/km |
Three Cores | 3x10 | 7 | 1 | 1.8 | 16.6 | 281 | 465 |
3x16 | 7 | 1 | 1.8 | 18.7 | 387 | 679 |
3x25 | 7 | 1.2 | 1.8 | 22.2 | 536 | 996 |
3x35 | 7 | 1.2 | 1.8 | 24.4 | 665 | 1311 |
3x50 | 19 | 1.4 | 1.9 | 28.1 | 863 | 1729 |
3x70 | 19 | 1.4 | 2 | 32.3 | 1153 | 2480 |
3x95 | 19 | 1.6 | 2.1 | 37.1 | 1563 | 3301 |
3x120 | 37 | 1.6 | 2.3 | 40.4 | 1850 | 4040 |
3x150 | 37 | 1.8 | 2.4 | 43.9 | 2258 | 5000 |
3x185 | 37 | 2 | 2.5 | 49.2 | 2819 | 6151 |
3x240 | 61 | 2.2 | 2.8 | 55.9 | 3577 | 8040 |
3x300 | 61 | 2.4 | 3 | 62.1 | 4413 | 9955 |
3x400 | 61 | 2.6 | 3.2 | 69.3 | 5512 | 12705 |
Four Cores | 4x10 | 7 | 1 | 1.8 | 18.1 | 343 | 589 |
4x16 | 7 | 1 | 1.8 | 20.5 | 487 | 874 |
4x25 | 7 | 1.2 | 1.8 | 24.3 | 677 | 1291 |
4x35 | 7 | 1.2 | 1.8 | 26.8 | 821 | 1681 |
4x50 | 19 | 1.4 | 2 | 31.2 | 1118 | 2273 |
4x70 | 19 | 1.4 | 2.1 | 35.8 | 1494 | 3264 |
4x95 | 19 | 1.6 | 2.3 | 41.2 | 1993 | 4312 |
4x120 | 37 | 1.6 | 2.4 | 44.8 | 2370 | 5291 |
4x150 | 37 | 1.8 | 2.5 | 48.7 | 2959 | 6615 |
4x185 | 37 | 2 | 2.7 | 54.7 | 3601 | 8044 |
4x240 | 61 | 2.2 | 3 | 62.1 | 4596 | 10547 |
4x300 | 61 | 2.4 | 3.2 | 69.1 | 5614 | 13004 |
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight |
STA | SWA |
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor |
mm2 | - | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
Three Cores |
3x35 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 24.7 | 28.2 | 912 | 1591 | 1447 | 2126 |
3x50 | 18 | 1.4 | 1 | 0.2 | 46/1.6 | 1.9 | 2 | 29.3 | 32.8 | 1202 | 2105 | 1842 | 2745 |
3x70 | 18 | 1.4 | 1.2 | 0.2 | 41/2.0 | 2.0 | 2.2 | 32.5 | 37.1 | 1520 | 2820 | 2475 | 3775 |
3x95 | 36 | 1.6 | 1.2 | 0.5 | 46/2.0 | 2.1 | 2.3 | 36.5 | 40.8 | 2241 | 4049 | 2989 | 4797 |
3x120 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.2 | 2.4 | 39.8 | 44.1 | 2617 | 4895 | 3435 | 5713 |
3x150 | 36 | 1.8 | 1.2 | 0.5 | 43/2.5 | 2.3 | 2.5 | 42.4 | 47.8 | 3019 | 5846 | 4258 | 7085 |
3x185 | 36 | 2 | 1.4 | 0.5 | 50/2.5 | 2.5 | 2.7 | 48.8 | 54.2 | 3783 | 7264 | 5219 | 8700 |
3x240 | 60 | 2.2 | 1.6 | 0.5 | 58/2.5 | 2.8 | 2.9 | 56 | 61.3 | 4790 | 9390 | 6444 | 11044 |
3x300 | 60 | 2.4 | 1.6 | 0.5 | 61/2.5 | 2.9 | 3.1 | 59.3 | 64.7 | 5594 | 11345 | 7458 | 13209 |
Four Cores with Reduced Neutral |
3x35+16 | 16-7 | 1.2-1 | 1 | 0.2 | 43/1.6 | 1.9 | 2 | 28.5 | 31.3 | 1107 | 1528 | 1705 | 2469 |
3x50+25 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 40/2.0 | 2.0 | 2.1 | 32.2 | 36.1 | 1410 | 2044 | 2326 | 3388 |
3x70+35 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 44/2.0 | 2.0 | 2.2 | 35.2 | 39.3 | 1733 | 2801 | 2762 | 4285 |
3x95+50 | 36-18 | 1.6-1.4 | 1.2 | 0.5 | 41/2.5 | 2.3 | 2.5 | 42.5 | 46.3 | 2656 | 3820 | 3816 | 5925 |
3x120+70 | 36-18 | 1.6-1.4 | 1.4 | 0.5 | 45/2.5 | 2.4 | 2.6 | 45.6 | 49.4 | 3137 | 4777 | 4391 | 7103 |
3x150+70 | 36-18 | 1.8-1.4 | 1.4 | 0.5 | 49/2.5 | 2.6 | 2.7 | 49.9 | 53.6 | 3660 | 5709 | 5043 | 8272 |
3x185+95 | 36-36 | 2-1.6 | 1.4 | 0.5 | 55/2.5 | 2.6 | 2.9 | 54.5 | 58.5 | 3445 | 7171 | 5902 | 9987 |
3x240+120 | 60-36 | 2.2-1.6 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3.1 | 61.6 | 65.3 | 5441 | 9272 | 7174 | 12552 |
3x300+150 | 60-36 | 1.4-1.8 | 1.6 | 0.5 | 67/2.5 | 3.8 | 3.2 | 65.9 | 69.6 | 6494 | 11546 | 8355 | 15067 |
Four Cores |
4x25 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 25.3 | 28 | 934 | 1576 | 1450 | 2092 |
4x35 | 16 | 1.2 | 1 | 0.2 | 41/1.6 | 1.8 | 1.9 | 27.4 | 30.2 | 1120 | 2017 | 1681 | 2578 |
4x50 | 18 | 1.4 | 1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.6 | 35.6 | 1454 | 2658 | 2336 | 3540 |
4x70 | 18 | 1.4 | 1.2 | 0.5 | 43/2.0 | 2.1 | 2.2 | 36.3 | 39 | 2183 | 3916 | 2840 | 4573 |
4x95 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.4 | 40.6 | 44.1 | 2748 | 5160 | 3545 | 5957 |
4x120 | 36 | 1.6 | 1.4 | 0.5 | 42/2.5 | 2.4 | 2.5 | 43.9 | 47.2 | 3237 | 6214 | 4334 | 7372 |
4x150 | 36 | 1.8 | 1.4 | 0.5 | 48/2.5 | 2.5 | 2.6 | 48.3 | 52 | 3853 | 7622 | 5148 | 8917 |
4x185 | 36 | 2 | 1.6 | 0.5 | 54/2.5 | 2.7 | 2.8 | 54.3 | 57.6 | 4756 | 9323 | 6132 | 10774 |
4x240 | 60 | 2.2 | 1.6 | 0.5 | 59/2.5 | 2.9 | 3 | 59.2 | 62.9 | 5774 | 11906 | 7374 | 13506 |
4x300 | 60 | 2.4 | 1.6 | 0.5 | 65/2.5 | 3 | 3.2 | 64.3 | 68.1 | 6922 | 14589 | 8624 | 16291 |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight |
STA | SWA |
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor |
mm2 | - | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
Three Cores |
3x10 | 7 | 1 | 1 | 0.2 | 35/1.25 | 1.8 | 1.8 | 19.4 | 21.5 | 494 | 679 | 988 | 1172 |
3x16 | 7 | 1 | 1 | 0.2 | 32/1.6 | 1.8 | 1.8 | 21.5 | 24.3 | 604 | 895 | 1051 | 1343 |
3x25 | 7 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.8 | 25 | 27.9 | 791 | 1252 | 1329 | 1790 |
3x35 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 950 | 1595 | 1551 | 2196 |
3x50 | 19 | 1.4 | 1.1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.3 | 35.2 | 1213 | 2079 | 2128 | 2994 |
3x70 | 19 | 1.4 | 1.2 | 0.5 | 45/2.0 | 2.1 | 2.2 | 35.6 | 40.1 | 1567 | 2894 | 2678 | 4005 |
3x95 | 19 | 1.6 | 1.3 | 0.5 | 42/2.5 | 2.3 | 2.4 | 42 | 46.2 | 2449 | 4188 | 3689 | 5428 |
3x120 | 37 | 1.6 | 1.3 | 0.5 | 45/2.5 | 2.4 | 2.5 | 45.3 | 49.6 | 2823 | 5014 | 4174 | 6364 |
3x150 | 37 | 1.8 | 1.4 | 0.5 | 49/2.5 | 2.5 | 2.7 | 48.9 | 53.2 | 3327 | 6069 | 4795 | 7537 |
3x185 | 37 | 2 | 1.5 | 0.5 | 56/2.5 | 2.7 | 2.8 | 54.5 | 58.7 | 4038 | 7371 | 5686 | 9019 |
3x240 | 61 | 2.2 | 1.6 | 0.5 | 63/2.5 | 2.9 | 3.1 | 61.4 | 65.2 | 4994 | 9457 | 6862 | 11325 |
3x300 | 61 | 2.4 | 1.7 | 0.5 | 70/2.5 | 3.2 | 3.3 | 67.9 | 71.7 | 6022 | 11564 | 8101 | 13643 |
3x400 | 61 | 2.6 | 1.9 | 0.5 | 62/3.15 | 3.4 | 3.6 | 75.4 | 80.5 | 7350 | 14543 | 10535 | 17728 |
Four Cores |
4x10 | 7 | 1 | 1 | 0.2 | 39/1.25 | 1.8 | 1.8 | 20.9 | 23 | 552 | 798 | 1073 | 1319 |
4x16 | 7 | 1 | 1 | 0.2 | 35/1.6 | 1.8 | 1.8 | 23.3 | 26.1 | 723 | 1110 | 1213 | 1601 |
4x25 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 959 | 1573 | 1559 | 2173 |
4x35 | 7 | 1.2 | 1 | 0.2 | 37/2.0 | 1.9 | 2 | 29.7 | 33.6 | 1140 | 2000 | 2006 | 2866 |
4x50 | 19 | 1.4 | 1.2 | 0.2 | 44/2.0 | 2.1 | 2.2 | 34.6 | 38.4 | 1524 | 2679 | 2541 | 3696 |
4x70 | 19 | 1.4 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.3 | 40.5 | 43.7 | 2338 | 4107 | 3187 | 4956 |
4x95 | 19 | 1.6 | 1.2 | 0.5 | 46/2.5 | 2.4 | 2.6 | 45.9 | 50.2 | 2955 | 5274 | 4325 | 6644 |
4x120 | 37 | 1.6 | 1.4 | 0.5 | 51/2.5 | 2.6 | 2.7 | 50 | 54.2 | 3466 | 6387 | 4568 | 7888 |
4x150 | 37 | 1.8 | 1.4 | 0.5 | 55/2.5 | 2.7 | 2.8 | 53.8 | 58.1 | 4144 | 7800 | 5772 | 9428 |
4x185 | 37 | 2 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3 | 60.2 | 64.5 | 4987 | 9430 | 6822 | 11266 |
4x240 | 61 | 2.2 | 1.6 | 0.5 | 70/2.5 | 3.1 | 3.3 | 67.7 | 71.5 | 6161 | 12111 | 8233 | 14184 |
4x300 | 61 | 2.4 | 1.6 | 0.5 | 61/3.15 | 3.4 | 3.5 | 74.7 | 78.8 | 7346 | 14735 | 10305 | 17694 |
Dirección:
Building 18, No. 283 Xisanhuan Road, High-Tech District, Zhengzhou, Henan, China
Tipo de Negocio:
Fabricante/Fábrica
Rango de Negocios:
Producto Eléctrico y Electrónico
Certificación del Sistema de Gestión:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Introducción de Empresa:
Henan Jiapu Cable Group está situado en Zhengzhou, el capital del centro de la provincia de Henan, también de la política, de la cultura, económico y del transporte. El grupo tiene 3 compañías subsidiarias que se especialicen en la fabricación y varias clases de abastecimiento de alambres y de cables. Con más de 15 años de esfuerzos y de revelado, se ha convertido en fabricante influyente de alambres y de cables que hacían la maquinaria en China.
Los productos principales son como siguen:
Conductor descubierto (AAC, AAAC, ACSR, ACAR, AACSR, ACSR/AW)
Bundled aéreo Cable 1kV-35kV (ABC Cable)
PVC Insulated (Flexible) Wire y PVC Insulated y Sheathed (Armoured) Power Cable
Bajo, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable
El cable de la soldadura, cable de control, caucho forró el cable
Podemos diseñar y fabricar los alambres y los cables según los estándares del GB, de JB, del IEC, de las BS, del estruendo, de ASTM, de JIS, del N-F, de AS/NZS, de CSA, del etc. Nuestros productos se han suministrado extensamente a los utilitarios de potencia, los distribuidores y los distribuidores autorizados eléctricos de los materiales, las firmas de la construcción y de ingeniería, los contratistas eléctricos o las compañías industriales por todo el mundo, así como África, Medio Oriente, Sur-este Asia, Suramérica, America Central, Norteamérica, Europa, Australia y así sucesivamente. Dar la bienvenida a sus pedidos del OEM y del ODM.
Estamos trabajando difícilmente todo el tiempo para mejorar las líneas de montaje, desarrollar nuevos productos, centrarse en las necesidades del cliente, e intentar nuestro mejor para ofrecer los mejores servicios profesionales, esforzarse cubrir las necesidades de los clientes. Perseguimos la puntería del "reputación y servicio de la calidad primero" y nos adherimos a los principales comerciales del "igualdad y beneficios mutuo". Ganamos la confianza de clientes domésticos y de clientes de diversos países. Tomaremos el alcohol de la empresa del "El Ley-respetar de la unidad y de Striving Reality y de Innovating Pioneering y de Progressing Honesty y de ". Y cordial cooperaremos con los amigos de varios círculos ambos en el país y en el extranjero con un nuevo gesto.